This script evaluates the Wigner matrix rotations and the commutator-relations involved and is available directly from the authors upon request. Crizotinib cell line The NMR sample of the ATP binding domain of DnaK from Thermus thermophilus was prepared as explained previously [16]. The protein concentration was ∼50 μM in 100% H2O containing 150 mM 15NH4Cl, 0.5 mM ADP, 50 mM (NH4)H2PO4, 5 mM MgCl2, 1 mM DTT, 1 mM NaN3 and 75 mM Tris pH 7.5. The NMR experiment shown in Fig. 4 is
a 1H-coupled 15N–1H HSQC, obtained from a standard 15H–1H HSQC by removing the 180° proton decoupling pulse during the indirect nitrogen evolution. The experiment was performed on a Bruker Avance III 500 MHz (11.7 T) spectrometer using an HCN inverse RT probe. The spectrum was recorded with 48 complex points in the indirect dimension, a sweep-width of 1000 Hz, and was processed using nmrPipe [42]. Dr. John Kirkpatrick is acknowledged for helpful discussions and for help with recording NMR spectra, Dr. Jochen Reinstein (MPI Heidelberg), Dr. Ralf Seidel and Petra Herde (MPI Dortmund) are acknowledged for providing purified
DnaK-ABD. We thank Dr. Christopher Waudby for critical reading of the manuscript. NDW acknowledges the Federation of European Biochemical Societies (FEBS) for a long-term postdoctoral fellowship. This research is supported by the Biotechnology and Biological Sciences Research Council (BBSRC). DFH is a BBSRC David Phillips Fellow. “
“Accurate
temperature control during NMR experiments is www.selleckchem.com/products/BKM-120.html a prerequisite for dynamic and structural investigations [1], [2] and [3]. This requirement is particularly challenging Interleukin-2 receptor in high-resolution solid-state spectroscopy with magic angle spinning (MAS) when employing high gas flow rates for driving and bearing, with a separate flow to control of the temperature. High-power radio-frequency (rf) irradiation and friction can lead to significant heating of the sample that cannot be monitored accurately by variable-temperature control units. Several approaches for determining the sample temperatures in solid-state NMR experiments have been reported. NMR thermometers can exploit the temperature dependence of the isotropic chemical shifts of specific compounds containing 13C [1], [2] and [3], 15N [4], 31P [5] and [6], 119Sn [7], [8] and [9], 207Pb [10], [11] and [12] and 1H [13] and [14]. Very recently, spin–lattice relaxation rates of 79Br in KBr powder have been exploited, in addition to chemical shifts, for the determination of the sample temperature under magic-angle spinning conditions over a wide temperature range from 20 to 320 K [15]. Monitoring isotropic chemical shifts to calibrate the sample temperature presupposes a perfect stability of the static magnetic field. It can be difficult to satisfy this requirement in solid-state NMR measurements. Solid-state NMR probes typically do not incorporate any field-frequency lock.